IsoTek
IsoTek, the DISCOVERY Series V5 GEMINI
IsoTek, the DISCOVERY Series V5 GEMINI
Couldn't load pickup availability
The V5 Gemini is the fully updated version of our compact, highly acclaimed EVO3 Polaris with just two outlets and a rated current of 10 A. The V5 Gemini is an affordable upgrade designed for all smaller audio or audio-video systems, or as a means of expanding the outputs of other IsoTek products using the System Link output. This achieves a fully star-shaped grounding.
Features
- Suitable for all audio, audio-video, and network systems
- Reduces radio frequency interference (RFI) by 35 dB
- A central filtering network eliminates common-mode and differential-mode interference
- Independent outputs prevent differential-mode crosstalk
- Overvoltage protection: 45,000 A
- Star-shaped ground wiring
- Internal wiring made of multi-strand, silver-plated 6N OFC copper with FEP dielectric
- Compatible with standard IEC C13/C15 power cables
- SYSTEM LINK output for expanding the 2 existing outputs while maintaining star-shaped ground wiring
- Available with UK, EU, US, AU & CH outlets
Sine Wave Correction
To ensure the best possible sound quality, the power grid must meet two basic requirements: a clean 50 Hz sine wave provided by a source with the lowest possible impedance and the absence of high-frequency noise. Low impedance ensures a nearly constant voltage, regardless of how much current is consumed in the vicinity. In reality, a fluctuation of around
5% can typically be expected. The very low impedance of the power grid, which is well below 1 ohm at 50 Hz, is not maintained when influenced by radio frequencies (> 50 ohms > 100 kHz) and acts like an antenna that practically attracts interference. IsoTek power filter circuits are designed to reduce impedance, operate reliably, and work well into the audio frequency band. Not only is solid electrical engineering used here, but the requirements of electrical safety are also reliably met.
Independent Outlets
The outlets of all IsoTek power filter components are wired completely independently of each other – there is no direct connection between them. Each outlet is individually connected to one of the unique IsoTek filter elements on the circuit board. Only with this high level of effort is it possible to prevent mutual interference between the connected components.
System Link
Several IsoTek products feature a System Link connection, which allows the power supply of multiple devices to be daisy-chained. This maintains a common ground (star-shaped ground distribution) and no additional wall outlets are required.
Warranty